Electronic Balasts for Compact Fluorescent Lamps

More than (just) an Electronic Ballast...
With more than 85 years of
experience in the development and
production of products for the lighting
industry, Vossloh-Schwabe has never
been more of a product pioneer
than now.
Vossloh-Schwabe is committed to
delivering products of the highest
quality standards coupled with the
greatest possible innovative power in
accordance with current standards
and directives.
We see more than just an electronic
ballast at VS – we see the pacemaker that makes everything tick.
114
Electronic Ballasts for TC and T Lamps
Electronic Ballasts for Compact
Fluorescent Lamps and Tubular
Fluorescent Lamps
Electronic ballasts
for compact fluorescent lamps
ELXs – Warm start
ELXc – Warm start – Linear casing shape
ELXc – Warm start – Compact casing shape
ELXd – Dimmable – Linear casing shape
ELXd – Dimmable – Compact casing shape
116–132
116
117
120–127
118–119
128–132
Electronic ballasts
for tubular fluorescent lamps
ELXs – Warm start
ELXc – Warm start – Linear casing shape
ELXd – Dimmable – Linear casing shape
ELXe – Instant start – Lineare casing shape
133–144
133
134–139
140–143
144
Accessories for dimmable electronic built-in ballasts
Technical details for fluorescent lamps
General technical details
Glossary
145
247–285
530–538
539–545
Electronic Ballasts for TC and T Lamps
115
ELXs – Warm Start
for Compact
Fluorescent Lamps
K20
K21
18
18
21
80
75
141,7
146,7
4,4
Electronic built-in ballasts
Casing: heat-resistant polyamide
Power factor: approx. 0.6
(depending on the lamp output)
DC voltage operation: 198–264 V
Push-in terminals with push-button: 0.5–1.5 mm2
RFI-suppressed
For luminaires of protection class I and II
Degree of protection: IP20
Fixing slots for screws M4
For lighting systems with
high switching frequency (> 5/day)
EOL shut down approved
acc. to EN 61347 Test 2
41
new>>
B U I LT- I N
TC
Lamp
Output
Type
Base
W
5
TC-SEL
2G7
Power consumption
W
1 x 5.0
7
TC-SEL
2G7
1 x 6.4
9
TC-SEL
2G7
1 x 8.0
10
11
TC-DEL
TC-DD
TC-DEL
TC-DD
TC-SEL
G24q-1
GR10q
G24q-1
GR10q
2G7
1
1
1
1
1
13
TC-DEL/-TEL
G24q-1/GX24q-1
1 x 12.5
TC-TEL
TC-DD
GR14q-1
GR10q
1 x 14.8
1 x 13.2
TC-TEL
TC-DEL/-TEL
GR14q-1
G24q-2/GX24q-2
1 x 17.4
1 x 15.3
TC-F/-L
2G10/2G11
1 x 16.0
22
T-R5
2GX13
1 x 19.1
24
TC-F/-L
2G10/2G11
1 x 20.0
new>> 14
16
new>> 17
18
x
x
x
x
x
9.3
9.3
9.3
9.3
10.8
1 x 20.8
26
TC-DEL/-TEL
G24q-3/GX24q-3
Circuit diagrams see pages 267 – 270
116
1 x 21.5
Electronic ballast
Type
Ref. No.
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
116.900
116.903
116.900
116.903
116.900
116.903
116.900
116.900
116.903
116.903
116.900
116.903
121.901
121.904
117.908
116.900
116.903
117.908
121.901
121.904
124.902
124.905
124.902
124.905
124.902
124.905
126.906
126.907
126.906
126.907
188661
188662
188661
188662
188661
188662
188661
188661
188662
188662
188661
188662
188663
188664
188934
188661
188662
188934
188663
188664
188665
188666
188665
188666
188665
188666
188667
188668
188667
188668
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A3 –15 to 55
A3 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A3 –15 to 55
A3 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 80
max. 80
max. 80
max. 75
max. 75
max. 80
max. 80
max. 80
max. 85
max. 85
max. 85
max. 85
max. 85
max. 85
max. 85
max. 85
max. 85
max. 85
System
Casing Output
K20
K21
K20
K21
K20
K21
K20
K20
K21
K21
K20
K21
K20
K21
K20
K20
K21
K20
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
W
6.1
6.1
7.5
7.5
8.8
8.8
10.2
10.3
10.2
10.3
11.8
11.8
15.5
15.5
17.0
15.1
15.1
18.5
16.9
16.9
17.9
17.9
21.2
21.2
21.4
21.4
22.9
22.9
23.4
23.4
ELXc – Warm Start for TC-F, TC-L Lamps
Electronic built-in ballasts
Casing: metal
Power factor: > 0.96
DC voltage
for operation: 176–264 V
M10/M11
for ignition: 198– 264 V
(ELXc 180.866, 280.538: DC voltage
cannot be reduced to 176 V)
Push-in terminals: 0.5–1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
RFI-suppressed
For luminaires of protection class I
Degree of protection: IP20
For lighting systems with
high switching frequency (> 5/day)
EOL shut down approved acc. to EN 61347 Test 2
TC
21
4,2
4,2
B U I LT- I N
350/412
Lamp
Output
Type
Base
W
18
2x18
24
2x24
36
2x36
40
2x40
55
2x55
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-L
TC-L
TC-L
TC-L
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G11
2G11
2G11
2G11
80
2x80
TC-L
TC-L
2G11
2G11
Power consumption
W
1 x 16.0
2 x 16.0
1 x 22.0
2 x 22.0
1 x 32.0
2 x 32.0
1 x 40.0
2 x 40.0
1 x 55.0
2 x 50.0
2 x 55.0
1 x 80.0
2 x 80.0
Circuit diagrams see pages 267 – 270
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
140.862
240.863
140.862
240.863
140.862
240.863
140.862
240.863
180.866
254.865
280.538
180.866
280.538
188140
188616
188140
188616
188140
188616
188140
188616
188144
188618
188619
188144
188619
30
4,2
4,2
359/425
350/412
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 50
A2 –15 to 50
A2 –15 to 55
A2 –15 to 50
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
System
Casing Output Luminous
factor
W
%
M10
19.0 109.0
M10
35.0 105.3
M10
27.0 109.0
M10
51.0 106.8
M10
35.0 101.0
M10
71.0
98.7
M10
46.0 104.0
M10
89.0 103.6
M10
62.0 107.3
M10
112.0
92.9
M11
120,0 100.0
M10
87.0
97.6
M11
175.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
117
359
349,5
1
(3,75)
Ø
4,1
21
4,
1
350
4,2
4,2
Electronic built-in ballasts
M9
Casing: metal
Dimming range:
approx. 1–100 % of lamp power
Power factor: ³ 0.95 at 100% operation
DC voltage
for operation: 154–276 V
for ignition: 198–264 V
Push-in terminals: 0.5–1 mm2
M23
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
4,75
RFI-suppressed
For luminaires of protection class I
Degree of protection: IP20
Fixing holes for screws M4
for lateral or base mounting
,1
For lighting systems with
Ø4
high switching frequency (> 5/day)
5
EOL shut down approved acc. to EN 61347 Test 2
28,5
ELXd – Dimmable for TC-F, TC-L Lamps
30,4
new>>
40
4,1
360
(5)
350
M22/M24
5
350/415
Ø4
,2
30
1–10 V
4,2
8
4
21
Ø4
,2
B U I LT- I N
118
TC
Electronic Ballasts for TC and T Lamps
350/415
360/423
ELXd – Dimmable 1–10 V for TC-F, TC-L lamps
Control voltage: DC 1–10 V
acc. to EN 60929 with earth leakage current 0.5 mA
(protected if connected to mains voltage)
For use with open- or closed-loop control units
Lamp
Output
Type
Base
W
new>> 18
new>> 2x18
new>> 24
TC-F/-L 2G10/2G11
TC-F/-L 2G10/2G11
TC-F/-L 2G10/2G11
new>> 2x24
TC-F/-L 2G10/2G11
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-L
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G11
new>> 2x40
TC-L
2G11
new>> 55
TC-L
2G11
new>> 2x55
TC-L
2G11
TC-L
2G11
new>>
new>>
new>>
3x24
4x24
36
2x36
40
80
Power consumption
W
1 x 16.0
2 x 16.0
1 x 22.0
1 x 23.0
2 x 22.0
2 x 23.0
3 x 24.0
4 x 24.0
1 x 32.0
2 x 32.0
1 x 42.0
1 x 38.0
2 x 42.0
2 x 38.0
1 x 51.0
1 x 54.0
2 x 51.0
2 x 54.0
1 x 80.0
Circuit diagrams see pages 267 – 270
1–10 V
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
118.718
218.719
118.718
124.607
218.719
224.608
324.623
424.624
136.720
236.721
136.720
139.609
236.721
239.610
158.722
154.611
258.723
254.612
180.613
new>>
188873
188874
188873
188336
188874
188337
188597
188598
188875
188876
188875
188338
188876
188339
188877
188340
188878
188341
188342
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
TC
B U I LT- I N
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
System
Casing Output Luminous
factor
W
%
M9
18.0 100.0
M9
36.0 100.0
M9
27.0 100.0
M22
26.0 100.0
M9
52.0 100.0
M24
49.0 100.0
M23
73.4 100.0
M23
97.6 100.0
M9
37.3 100.0
M9
72.0 100.0
M9
46.4 100.0
M22
42.0 100.0
M9
92.5 100.0
M24
82.0 100.0
M9
56.0 100.0
M22
59.0 100.0
M9
110.5 100.0
M24
115.0 100.0
M22
88.0 100.0
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 75
max. 70
max. 75
max. 75
max. 75
max. 70
max. 70
max. 70
max. 75
max. 70
max. 75
max. 70
max. 75
max. 75
max. 75
max. 75
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXd – Dimmable with push key or DALI for TC-F, TC-L lamps
Complete implementation of the DALI-standard:
addressable, memory store for scenes and groups,
revertive information communication, physical and
RND-selection, standardized lamp characteristic
Low-power design ensures very low standby
power consumption
Stand-by power consumption: £ 0.2 W
Lamp
Output
Type
Base
W
18
2x18
24
2x24
3x24
4x24
36
2x36
40
2x40
55
2x55
80
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-F/-L
TC-L
TC-L
TC-L
TC-L
TC-L
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G10/2G11
2G11
2G11
2G11
2G11
2G11
Power consumption
W
1 x 16.0
2 x 16.0
1 x 23.0
2 x 23.0
3 x 23.0
4 x 23.0
1 x 32.0
2 x 32.0
1 x 38.0
2 x 38.0
1 x 54.0
2 x 54.0
1 x 80.0
Circuit diagrams see pages 267 – 270
B U I LT- I N
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
118.615
218.616
124.600
224.601
324.626
424.628
136.617
236.618
139.602
239.621
154.603
254.604
180.605
188344
188345
188329
188330
188600
188602
188346
188347
188331
188350
188332
188333
188334
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
TC
System
Casing Output Luminous
factor
W
%
M22
19.0 100.0
M24
37.0 100.0
M22
26.0 100.0
M24
49.0 100.0
M23
73.4 100.0
M23
97.6 100.0
M22
36.0 100.0
M24
69.0 100.0
M22
42.0 100.0
M24
82.0 100.0
M22
59.0 100.0
M24
115.0 100.0
M22
88.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
119
new>>
ELXc – Warm Start for Compact Fluorescent Lamps
Electronic ballasts
Casing: heat-resistant polyamide (K2, K3)
or heat-resistant polycarbonate (K1, K4)
Power factor: > 0.96 (K1: 0.9)
DC voltage
for operation: 176–264 V
for ignition: 198–264 V
(ELXc 242.837: DC voltage cannot
be reduced to 176 V)
Push-in terminals with push-button:
0.5–1.5 mm2
RFI-suppressed
Constant power consumption
For luminaires of protection class I and II
Degree of protection: IP20
Fixing brackets for screws M4
for lateral or base mounting
For lighting systems with
high switching frequency (> 5/day)
EOL shut down approved acc. to EN 61347 Test 2
ELXc 120.838 in K4+ casing with venting slits
(drawing see page 129)
INDEPENDENT
TC
B U I LT- I N
120
Electronic Ballasts for TC and T Lamps
ELXc – Warm Start for Compact Fluorescent Lamps
new>>
TC
B U I LT- I N
K1
K3
74
99
4,2
4
33
29
4,2
4
93
123
83,5
79
67
)
4,2
(96
58
48,5
111
0)
4,2
(13
K2
K4
134
83,5
4,2
4
4
31
38
4,2
158
94
146
)
90
0
(11
102
67
58
103
1)
4,2
4,2
(17
TC
134
33
2,5
4
195
183
79
102
147,1
67,4
5,5
4,5
5,4
159
4,5
67
57,4
4,5
30
31
28
3
140
130
99
4,2
38
83,5
4,2
4,5
K4 with cord grip
K3 with cord grip
28
K2 with cord grip
90
INDEPENDENT
99
4,2
117,3
4,5
146
Electronic Ballasts for TC and T Lamps
121
new>>
ELXc – Warm start for compact fluorescent lamps
Built-in ballasts
ELXc 213.870, 218.871, 142.872,
242.837, 155.378 have a second earth terminal
to ground the luminaires for example
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
5
7
9
TC-SEL
TC-SEL
TC-SEL
2G7
2G7
2G7
Power consumption
W
1 x 5.0
1 x 6.5
1 x 8.0
2x9
10
TC-SEL
TC-DEL
2G7
G24q-1
2 x 8.0
1 x 9.5
2x10
11
TC-DEL
TC-SEL
G24q-1
2G7
2 x 9.5
1 x 11.0
2x11
13
TC-SEL
2G7
2 x 11.0
TC-DEL/-TEL G24q-1/GX24q-1 1 x 12.5
2x13
14
2x14
17
2x17
18
TC-DEL/-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-DEL/-TEL
TC-F/-L
TC-DEL/-TEL
TC-F/-L
G24q-1/GX24q-1
GR14q-1
GR14q-1
GR14q-1
GR14q-1
G24q-2/GX24q-2
2G10/2G11
G24q-2/GX24q-2
2G10/2G11
2
1
2
1
2
1
1
2
2
22
T-R5
2GX13
1 x 22.0
22+40
T-R5
2GX13
2x22
24
T-R5
TC-F/-L
2GX13
2G10/2G11
2x24
TC-F/-L
2G10/2G11
1x
22+40
2 x 22.0
1 x 22.0
1 x 22.5
2 x 22.0
26
2x26
TC-DEL/-TEL G24q-3/GX24q-3 1 x 24.0
TC-DEL/-TEL G24q-3/GX24q-3 2 x 24.0
2x18
Circuit diagrams see pages 267 – 270
122
x
x
x
x
x
x
x
x
x
12.5
14.8
14.8
18.4
18.4
16.5
16.0
16.5
16.0
TC
B U I LT- I N
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
113.392
113.392
113.392
213.870
213.870
113.392
213.870
213.870
113.392
213.870
213.870
113.392
213.870
213.870
217.873
217.873
217.873
217.873
218.871
142.872
218.871
242.837
142.872
142.872
128.869
242.837
188454
188454
188454
188698
188698
188454
188698
188698
188454
188698
188698
188454
188698
188698
188760
188760
188760
188760
188699
188700
188699
188643
188700
188700
188589
188643
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
242.837
142.872
128.869
242.837
142.872
142.872
242.837
257.836
142.872
188643
188700
188589
188643
188700
188700
188643
188132
188700
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 55
A2 –20 to 55
A2 –20 to 55
A2 –20 to 50
A2 –20 to 50
A3 –20 to 55
A2 –20 to 50
A2 –20 to 50
A2 –20 to 55
A2 –20 to 50
A2 –20 to 50
A3 –20 to 55
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
Casing
temperature
tc (°C)
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 70
max. 65
System
Casing Output Luminous
factor
W
%
K1
6.5
100.0
K1
8.0
100.0
K1
10.0
100.0
K2
10.7
102.9
K2
19.4
102.9
K1
11.5
106.0
K2
10.9
99.2
K2
20.5
98.8
K1
13.5
100.0
K2
14.7
110.1
K2
27.9
116.1
K1
15.0
100.0
K2
15.0
102.9
K2
28.1
110.9
K2
18.0
100.0
K2
34.0
102.0
K2
22.0
99.0
K2
41.5
102.0
K2
21.0
104.8
K2
18.0
102.0
K2
38.0
100.7
K3
35.0
104.3
K2
34.0
98.0
K2
26.0
103.0
K2
25.0
96.7
K3
68.0
100.0
A2
A2
A2
A2
A2
A2
A2
A2
A2
max.
max.
max.
max.
max.
max.
max.
max.
max.
K3
K2
K2
K3
K2
K2
K3
K4
K2
–20
–20
–20
–20
–20
–20
–20
–20
–20
to
to
to
to
to
to
to
to
to
50
50
50
50
50
50
50
50
50
65
65
70
65
65
65
65
70
65
48.5
27.0
25.0
48.5
47.0
26.0
53.0
52.0
53.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
105.8
105.0
95.8
106.2
102.0
104.0
106.1
106.2
105.0
ELXc – Warm start for compact fluorescent lamps
Built-in ballasts
ELXc 213.870, 218.871, 142.872,
242.837, 155.378 have a second earth terminal
to ground the luminaires for example
Lamp
Output
Type
Base
W
28
32
2x32
TC-DD
TC-TEL
TC-TEL
GR10q
GX24q-3
GX24q-3
Power consumption
W
1 x 26.0
1 x 32.0
2 x 32.0
TC-F/-L
TC-F/-L
TC-DD
TC-DD
TC-L
T-R5
TC-L
T-R5
TC-TEL
TC-TEL
2G10/2G11
2G10/2G11
GR10q
GR10q
2G11
2GX13
2G11
2GX13
GX24q-4
GX24q-4
1
2
1
2
1
1
2
2
1
2
x
x
x
x
x
x
x
x
x
x
TC-L
T-R5
TC-TEL
TC-TEL
TC-TEL
T-R5
TC-TEL
TC-TEL
TC-L
TC-TEL
TC-TEL
2G11
2GX13
GX24q-5
GX24q-5
2G8
2GX13
2G8
GX24q-6
2G11
2G8
2G8
1
1
1
2
1
1
2
1
1
1
1
x
x
x
x
x
x
x
x
x
x
x
36
2x36
38
2x38
40
2x40
42
2x42
55
57
2x57
60
2x60
70
80
85
120
Circuit diagrams see pages 267 – 270
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
32.0 ELXc
32.0 ELXc
36.0 ELXc
36.0 ELXc
40.0 ELXc
40.0 ELXc
40.0 ELXc
40.0 ELXc
42.0 ELXc
43.0 ELXc
ELXc
55.6 ELXc
55.6 ELXc
57.0 ELXc
57.5 ELXc
63.0 ELXc
60.6 ELXc
63.0 ELXc
70.0 ELXc
80.5 ELXc
87.0 ELXc
122.0 ELXc
128.869
142.872
242.837
257.836
142.872
242.837
142.872
242.837
142.872
142.872
242.837
242.837
142.872
242.837
257.836
155.378
155.378
170.833
257.836
120.838
155.378
120.838
170.833
155.378
120.838
120.838
TC
B U I LT- I N
188589
188700
188643
188132
188700
188643
188700
188643
188700
188700
188643
188643
188700
188643
188132
188680
188680
188682
188132
188238
188680
188238
188682
188680
188238
188238
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 60
A2 –20 to 50
A2 –20 to 60
A2 –20 to 50
A2 –20 to 50
A2 –20 to 60
A2 –20 to 60
Casing
temperature
tc (°C)
max. 70
max. 65
max. 65
max. 70
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 70
max. 70
max. 70
max. 65
max. 70
max. 70
max. 70
max. 70
max. 65
max. 70
max. 70
max. 70
System
Casing Output Luminous
factor
W
%
K2
32.0 98.1
K2
33.0 102.0
K3
70.5 104.8
K4
70.0 109.4
K2
34.0 105.0
K3
70.5 101.8
K2
38.0 95.0
K3
79.2 101.3
K2
43.0 99.0
K2
41.0 96.0
K3
88.0 101.3
K3
88.0 101.1
K2
45.0 99.0
K3
94.5 100.6
K4
94.0 104.9
K3
60.0 102.4
K3
60.0 101.2
K3
63.0 105.0
K4
130.0 100.0
K4+
70.0 106.1
K3
66.0 109.5
K4+
139.0 100.0
K3
77.0 110.0
K3
88.0 101.3
K4+
96.0 100.0
K4+
134.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
123
new>>
ELXc – Warm start for compact fluorescent lamps – Independent ballasts
ELXc 257.836:
loop-through the mains supply is possible
ELXc 213.870, 218.871, 142.872,
242.837, 155.378 have a second earth terminal
to ground the luminaires for example
Lamp
Output
new>>
new>>
new>>
new>>
Type
Base
TC-SEL
TC-SEL
TC-DEL
TC-DEL
TC-SEL
TC-SEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-DEL/-TEL
TC-F/-L
TC-DEL/-TEL
TC-F/-L
2G7
2G7
G24q-1
G24q-1
2G7
2G7
G24q-1/GX24q-1
G24q-1/GX24q-1
GR14q-1
GR14q-1
GR14q-1
GR14q-1
G24q-2/GX24q-2
2G10/2G11
G24q-2/GX24q-2
2G10/2G11
Power consumption
W
1 x 8.0
2 x 8.0
1 x 9.5
2 x 9.5
1 x 11.0
2 x 11.0
1 x 12.5
2 x 12.5
1 x 14.8
2 x 14.8
1 x 18.4
2 x 18.4
1 x 16.5
1 x 16.0
2 x 16.5
2 x 16.0
T-R5
2GX13
1 x 22.0
22+40 T-R5
2GX13
2x22
24
2GX13
2G10/2G11
2G10/2G11
2G10/2G11
1x
22+40
2 x 22.0
1 x 22.0
1 x 22.5
2 x 22.0
W
9
2x9
10
2x10
11
2x11
13
2x13
14
2x14
17
2x17
18
2x18
22
2x24
T-R5
TC-F/-L
TC-F/-L
TC-F/-L
26
2x26
TC-DEL/-TEL G24q-3/GX24q-3 1 x 24.0
TC-DEL/-TEL G24q-3/GX24q-3 2 x 24.0
Circuit diagrams see pages 267 – 270
124
TC
INDEPENDENT
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
213.870
213.870
213.870
213.870
213.870
213.870
213.870
213.870
217.873
217.873
217.873
217.873
218.871
142.872
218.871
242.837
142.872
142.872
128.869
242.837
188712
188712
188712
188712
188712
188712
188712
188712
188761
188761
188761
188761
188713
188714
188713
188687
188714
188714
188590
188687
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
242.837
142.872
128.869
242.837
142.872
142.872
242.837
257.836
142.872
188687
188714
188590
188687
188714
188714
188687
188400
188714
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
Casing
temperature
tc (°C)
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 70
max. 65
System
Casing Output Luminous
factor
W
%
K2
10.7
102.9
K2
19.4
102.9
K2
10.9
99.2
K2
20.5
98.8
K2
14.7
110.1
K2
27.9
116.1
K2
15.0
102.9
K2
28.1
110.9
K2
18.0
100.0
K2
34.0
102.0
K2
22.0
99.0
K2
41.5
102.0
K2
21.0
104.8
K2
18.0
102.0
K2
38.0
100.7
K3
35.0
104.3
K2
34.0
98.0
K2
26.0
103.0
K2
25.0
96.7
K3
68.0
100.0
A2
A2
A2
A2
A2
A2
A2
A3
A2
max.
max.
max.
max.
max.
max.
max.
max.
max.
K3
K2
K2
K3
K2
K2
K3
K4
K2
–20
–20
–20
–20
–20
–20
–20
–20
–20
to
to
to
to
to
to
to
to
to
50
50
50
50
50
50
50
50
50
65
65
70
65
65
65
65
70
65
48.5
27.0
25.0
48.5
47.0
26.0
53.0
52.0
53.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
105.8
105.0
95.8
106.2
102.0
104.0
106.1
106.2
105.0
ELXc – Warm start for compact fluorescent lamps – Independent ballasts
ELXc 257.836:
loop-through the mains supply is possible
ELXc 213.870, 218.871, 142.872,
242.837, 155.378 have a second earth terminal
to ground the luminaires for example
Lamp
Output
Type
Base
W
28
32
2x32
TC-DD
TC-TEL
TC-TEL
GR10q
GX24q-3
GX24q-3
Power consumption
W
1 x 26.0
1 x 32.0
2 x 32.0
TC-F/-L
TC-F/-L
TC-DD
TC-DD
TC-L
T-R5
TC-L
T-R5
TC-TEL
TC-TEL
2G10/2G11
2G10/2G11
GR10q
GR10q
2G11
2GX13
2G11
2GX13
GX24q-4
GX24q-4
1
2
1
2
1
1
2
2
1
2
x
x
x
x
x
x
x
x
x
x
32.0
32.0
36.0
36.0
40.0
40.0
40.0
40.0
42.0
43.0
TC-L
T-R5
TC-TEL
TC-TEL
TC-TEL
T-R5
TC-TEL
TC-TEL
TC-L
TC-TEL
TC-TEL
2G11
2GX13
GX24q-5
GX24q-5
2G8
2GX13
2G8
GX24q-6
2G11
2G8
2G8
1
1
1
2
1
1
2
1
1
1
1
x
x
x
x
x
x
x
x
x
x
x
55.6
55.6
57.0
57.0
63.0
60.6
63.0
70.0
80.5
87.0
122.0
36
2x36
38
2x38
40
2x40
42
2x42
55
57
2x57
60
2x60
70
80
85
120
Circuit diagrams see pages 267 – 270
INDEPENDENT
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
128.869
142.872
242.837
257.836
142.872
242.837
142.872
242.837
142.872
142.872
242.837
242.837
142.872
242.837
257.836
155.378
155.378
170.833
257.836
120.838
155.378
120.838
170.833
155.378
120.838
120.838
188590
188714
188687
188400
188714
188687
188714
188687
188714
188714
188687
188687
188714
188687
188400
188681
188681
188683
188400
188273
188681
188273
188683
188681
188273
188273
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 60
A2 –20 to 50
A2 –20 to 60
A2 –20 to 50
A2 –20 to 50
A2 –20 to 60
A2 –20 to 60
Casing
temperature
tc (°C)
max. 70
max. 65
max. 65
max. 70
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 70
max. 70
max. 70
max. 65
max. 70
max. 70
max. 70
max. 70
max. 65
max. 70
max. 70
max. 70
TC
System
Casing Output Luminous
factor
W
%
K2
32.0
98.1
K2
33.0 102.0
K3
70.5 104.8
K4
70.0 109.4
K2
34.0 105.0
K3
70.5 101.8
K2
38.0
95.0
K3
79.2 101.3
K2
43.0
99.0
K2
41.0
96.0
K3
88.0 101.3
K3
88.0 101.1
K2
45.0
99.0
K3
94.5 100.6
K4
94.0 104.9
K3
60.0 102.4
K3
60.0 101.2
K3
63.0 105.0
K4
130.0 100.0
K4+
70.0 106.1
K3
66.0 109.5
K4+
139.0 100.0
K3
77.0 110.0
K3
88.0 101.3
K4+
96.0 100.0
K4+
134.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
125
new>>
ELXc – Warm start for compact fluorescent lamps – Independent ballasts
Mains and earth through-wiring on primary side is possible
Existing terminals: 2x L; 2x N; 3x PE
Lamp
Output Type
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
W
9
2x9
10
2x10
11
2x11
13
2x13
18
2x18
TC-SEL
TC-SEL
TC-DEL
TC-DEL
TC-SEL
TC-SEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-F/-L
TC-DEL/-TEL
TC-F/-L
Base
2G7
2G7
G24q-1
G24q-1
2G7
2G7
G24q-1/GX24q-1
G24q-1/GX24q-1
G24q-2/GX24q-2
2G10/2G11
G24q-2/GX24q-2
2G10/2G11
22
T-R5
22+40 T-R5
2GX13
2GX13
2x22
24
2x24
T-R5
TC-F/-L
TC-F/-L
2GX13
2G10/2G11
2G10/2G11
26
2x26
TC-DEL/-TEL G24q-3/GX24q-3 1 x 24.0
TC-DEL/-TEL G24q-3/GX24q-3 2 x 24.0
Circuit diagrams see pages 267 – 270
126
Power consumption
W
1 x 8.0
2 x 8.0
1 x 9.5
2 x 9.5
1 x 11.0
2 x 11.0
1 x 12.5
2 x 12.5
1 x 16.5
1 x 16.0
2 x 16.5
2 x 16.0
1 x 22.0
1x
22+40
2 x 22.0
1 x 22.0
2 x 22.0
TC
INDEPENDENT
Electronic ballast
Type
Ref. No. Voltage AC
50, 60 Hz
V±10 %
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 213.874 188886 220 – 240
ELXc 218.875 188887 220 – 240
ELXc 142.876 188888 220 – 240
ELXc 218.875 188887 220 – 240
ELXc 242.877 188889 220 – 240
ELXc 142.876 188888 220 – 240
ELXc 142.876 188888 220 – 240
ELXc 242.877 188889 220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
Casing
temperature
tc (°C)
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
Casing
System
Output
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
W
10.7
19.4
10.9
20.5
14.7
27.9
15.0
28.1
21.0
18.0
38.0
35.0
34.0
26.0
68.0
Luminous
factor
%
102.9
102.9
99.2
98.8
110.1
116.1
102.9
110.9
104.8
102.0
100.7
104.3
98.0
103.0
100.0
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
A2
A2
A2
A2
A2
A2
A2
max.
max.
max.
max.
max.
max.
max.
K3
K3
K3
K3
K3
K3
K3
48.5
27.0
48.5
47.0
26.0
53.0
53.0
105.8
105.0
106.2
102.0
104.0
106.1
105.0
242.877
142.876
242.877
142.876
142.876
242.877
142.876
188889
188888
188889
188888
188888
188889
188888
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
–20
–20
–20
–20
–20
–20
–20
to
to
to
to
to
to
to
50
50
50
50
50
50
50
65
65
65
65
65
65
65
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
ELXc – Warm start for compact fluorescent lamps – Independent ballasts
Mains and earth through-wiring on primary side is possible
Existing terminals: 2x L; 2x N; 3x PE
Lamp
Output
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
W
32
2x32
36
2x36
38
2x38
40
2x40
42
2x42
Type
Base
TC-TEL
TC-TEL
TC-F/-L
TC-F/-L
TC-DD
TC-DD
TC-L
T-R5
TC-L
T-R5
TC-TEL
TC-TEL
GX24q-3
GX24q-3
2G10/2G11
2G10/2G11
GR10q
GR10q
2G11
2GX13
2G11
2GX13
GX24q-4
GX24q-4
Circuit diagrams see pages 267 – 270
Power consumption
W
1 x 32.0
2 x 32.0
1 x 32.0
2 x 32.0
1 x 36.0
2 x 36.0
1 x 40.0
1 x 40.0
2 x 40.0
2 x 40.0
1 x 42.0
2 x 43.0
142.876
242.877
142.876
242.877
142.876
242.877
142.876
142.876
242.877
242.877
142.876
242.877
TC
INDEPENDENT
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
new>>
188888
188889
188888
188889
188888
188889
188888
188888
188889
188889
188888
188889
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
A2 –20 to 50
Casing
temperature
tc (°C)
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
max. 65
System
Casing Output
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
K3
W
33.0
70.5
34.0
70.5
38.0
79.2
43.0
41.0
88.0
88.0
45.0
94.5
Luminous
factor
%
102.0
104.8
105.0
101.8
95.0
101.3
99.0
96.0
101.3
101.1
99.0
100.6
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
127
new>>
ELXd – Dimmable for TC-DEL, TC-TEL Lamps
RFI-suppressed, Degree of protection: IP20
For luminaires of protection class I
Fixing brackets for screws M4
for lateral or base mounting
For lighting systems with
high switching frequency (> 5/day)
Electronic ballasts
Casing: heat-resistant polyamide (K2/K3)
or heat-resistant polycarbonate (K4)
Dimming range:
approx. 3–100% of lamp power
Push-in terminals with push-button: 0.5–1.5 mm²
1–10 V
TC
B U I LT- I N
K2
K3
83,5
99
4,2
4
4
33
31
4,2
111
67
67
0)
(13
0)
4,2
4,2
(11
79
123
94
58
103
K4+ with venting slits
K4
134
134
4,2
4
4
38
38
4,2
146
90
90
128
(17
Electronic Ballasts for TC and T Lamps
4,2
1)
4,2
(17
102
158
146
102
158
1)
EOL shut down approved
acc. to EN 61347 Test 2
ELXd – Dimmable for TC-DEL, TC-TEL Lamps
1–10 V
TC
INDEPENDENT
K2 with cord grip
K3 with cord grip
83,5
33
4
159
147,1
79
67,4
67
57,4
4,5
130
5,4
30
31
28
140
3
99
4,2
4,2
4,5
new>>
99
4,5
4,2
117,3
K4+ with cord grip and
venting slits
K4 with cord grip
134
134
38
28
38
28
195
2,5
195
2,5
5,5
4,5
5,5
4,5
183
4,5
102
90
90
102
183
4,5
146
146
TC
B U I LT- I N
84
Cord grip for K3.1
(17,9)
35,7
82
(6)
111
(24)
6
(16,1)
151,7
167,8
17,9
6
24
67
79
,6
Ø3
48
4,5
(6)
123
36
33
K3.1
Electronic Ballasts for TC and T Lamps
129
ELXd – Dimmable 1–10 V for TC-DEL, TC-TEL lamps
Electronic built-in ballasts
Casing: K3, K4 and K4+ with venting slits
Control voltage: DC 1–10 V acc. to
EN 60929 with earth leakage current 0.5 mA
(protected if connected to mains voltage)
For use with open- or closed-loop control units
Power factor: 0.98 at 100 % operation
Lamp
Output
Type
Base
W
18
2x18
26
2x26
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
G24q-2/GX24q-2
G24q-2/GX24q-2
G24q-3/GX24q-3
G24q-3/GX24q-3
Power consumption
W
1 x 16.5
2 x 16.5
1 x 24.0
2 x 24.0
32
2x32
42
2x42
57
70
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
GX24q-3
GX24q-3
GX24q-4
GX24q-4
GX24q-5
GX24q-6
1
2
1
2
1
1
Circuit diagrams see pages 267 – 270
x
x
x
x
x
x
32.0
32.0
43.0
43.0
57.0
70.0
DC voltage
for operation: 176– 264 V
for ignition: 198– 264 V
1–10 V
B U I LT- I N
TC
Electronic ballast
Type
Ref. No. Voltage AC
50, 60 Hz
V±10 %
ELXd 118.802 188564 220 – 240
ELXd 218.803 188549 220 – 240
ELXd 142.806 188565 220 – 240
ELXd 242.807 188550 220 – 240
ELXd 226.801 188431 220 – 240
ELXd 142.806 188565 220 – 240
ELXd 242.807 188550 220 – 240
ELXd 142.806 188565 220 – 240
ELXd 242.807 188550 220 – 240
ELXd 170.808 188276 220 – 240
ELXd 170.808 188276 220 – 240
EE* Ambient
temperature
ta (°C)
A1 5 to 55
A1 5 to 55
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 55
A1 10 to 55
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 60
max. 60
System
Casing Output Luminous
factor
W
%
K3
21.0 100.0
K4
38.0 100.0
K3
27.0 100.0
K4
53.0 100.0
K3
54.0 100.0
K3
36.0 100.0
K4
71.0 100.0
K3
46.0 100.0
K4
92.0 100.0
K4+
62.0 100.0
K4+
77.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXd – Dimmable 1–10 V for TC-DEL, TC-TEL lamps
Independent electronic ballasts
Casing with cord grip: K3, K4 and
K4+ with venting slits
Control voltage: DC 1–10 V acc. to
EN 60929 with earth leakage current 0.5 mA
(protected if connected to mains voltage)
For use with open- or closed-loop control units
Power factor: 0.98 at 100 % operation
Lamp
Output Type
Base
W
18
2x18
26
2x26
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
G24q-2/GX24q-2
G24q-2/GX24q-2
G24q-3/GX24q-3
G24q-3/GX24q-3
Power consumption
W
1 x 16.5
2 x 16.5
1 x 24.0
2 x 24.0
32
2x32
42
2x42
57
70
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-TEL
GX24q-3
GX24q-3
GX24q-4
GX24q-4
GX24q-5
GX24q-6
1
2
1
2
1
1
Circuit diagrams see pages 267 – 270
130
x
x
x
x
x
x
32.0
32.0
43.0
43.0
57.0
70.0
DC voltage
for operation: 176– 264 V
for ignition: 198– 264 V
1–10 V
INDEPENDENT
TC
Electronic ballast
Type
Ref. No. Voltage AC
50, 60 Hz
V±10 %
ELXd 118.802 188694 220 – 240
ELXd 218.803 188696 220 – 240
ELXd 142.806 188695 220 – 240
ELXd 242.807 188697 220 – 240
ELXd 226.801 188490 220 – 240
ELXd 142.806 188695 220 – 240
ELXd 242.807 188697 220 – 240
ELXd 142.806 188695 220 – 240
ELXd 242.807 188697 220 – 240
ELXd 170.808 188495 220 – 240
ELXd 170.808 188495 220 – 240
EE* Ambient
temperature
ta (°C)
A1 5 to 55
A1 5 to 55
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 55
A1 10 to 55
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 60
max. 60
System
Casing Output Luminous
factor
W
%
K3
21.0
100.0
K4
38.0
100.0
K3
27.0
100.0
K4
53.0
100.0
K3
54.0
100.0
K3
36.0
100.0
K4
71.0
100.0
K3
46.0
100.0
K4
92.0
100.0
K4+
62.0
100.0
K4+
77.0
100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
ELXd – Dimmable with push key or DALI for TC-DEL, TC-TEL lamps
Electronic built-in ballasts
PUSH: dimmable with usual push key
and sensor
DALI: poles are not polarity sensitive
(protected if connected to mains voltage)
for use with DALI compatible control units
Automatic restart after lamp has been changed
Power factor: > 0.95 at 100 % operation
DC voltage
for operation: 154–276 V
(ELXd 117.715, ELXd 217.717
and ELXd 142.709: 176–264 V)
for ignition: 198– 264 V
Suitable for operation of Amalgam lamps
Stand-by power consumption: £ 0.2 W
(ELXd 117.715, 217.717, 142.709: £ 0.5 W)
new>>
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
14
2x14
17
2x17
18
2x18
26
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
GR14q-1
GR14q-1
GR14q-1
GR14q-1
G24q-2/GX24q-2
G24q-2/GX24q-2
G24q-3/GX24q-3
2x26
32
TC-DEL/-TEL G24q-3/GX24q-3
TC-TEL
GX24q-3
2x32
42
TC-TEL
TC-TEL
GX24q-3
GX24q-4
2x42
57
TC-TEL
TC-TEL
GX24q-4
GX24q-5
Circuit diagrams see pages 267 – 270
Power consumption
W
1 x 14.8
2 x 14.8
1 x 18.4
2 x 18.4
1 x 18.0
2 x 18.0
1 x 26.0
1 x 27.5
2 x 26.0
1 x 32.0
1 x 34.5
2 x 32.0
1 x 42.0
1 x 45.0
2 x 42.0
1 x 57.0
new>>
Complete implementation of the DALI-standard:
addressable, memory store for scenes and groups,
revertive information communication, physical and
RND-selection, standardized lamp characteristic
Low-power design ensures very low standby
power consumption
B U I LT- I N
TC
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
117.715
217.717
117.715
217.717
157.812
242.813
157.812
142.709
242.813
157.812
142.709
242.813
157.812
142.709
242.813
157.812
188864
188866
188864
188866
188715
188716
188715
188923
188716
188715
188923
188716
188715
188923
188716
188715
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 60
A1 10 to 50
A1 10 to 60
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
Casing
temperature
tc (°C)
max. 65
max. 70
max. 65
max. 70
max. 75
max. 75
max. 75
max. 65
max. 75
max. 75
max. 65
max. 75
max. 75
max. 65
max. 75
max. 75
System
Casing Output Luminous
factor
W
%
K2
18.0
103.8
K3
33.8
98.5
K2
22.0
105.3
K3
40.7
102.5
K3.1 20.0
100.0
K3.1 38.0
100.0
K3.1 29.0
100.0
K2
27.5
106.8
K3.1 56.0
100.0
K3.1 36.0
100.0
K2
34.5
106.3
K3.1 69.0
100.0
K3.1 47.0
100.0
K2
45.0
103.8
K3.1 90.0
100.0
K3.1 61.0
100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
131
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
ELXd – Dimmable with push key or DALI for TC-DEL, TC-TEL lamps
Independent electronic ballasts
PUSH: dimmable with usual push key
and sensor
DALI: poles are not polarity sensitive
(protected if connected to mains voltage)
for use with DALI compatible control units
Automatic restart after lamp has been changed
Power factor: > 0.95 at 100 % operation
DC voltage
for operation: 154–276 V
(ELXd 117.715, ELXd 217.717
and ELXd 142.709: 176–264 V)
for ignition: 198–264 V
Suitable for operation of Amalgam lamps
Stand-by power consumption: £ 0.2 W
(ELXd 117.715, 217.717, 142.709: £ 0.5 W)
Lamp
Output
Type
Base
W
14
2x14
17
2x17
18
2x18
26
TC-TEL
TC-TEL
TC-TEL
TC-TEL
TC-DEL/-TEL
TC-DEL/-TEL
TC-DEL/-TEL
GR14q-1
GR14q-1
GR14q-1
GR14q-1
G24q-2/GX24q-2
G24q-2/GX24q-2
G24q-3/GX24q-3
2x26
32
TC-DEL/-TEL G24q-3/GX24q-3
TC-TEL
GX24q-3
2x32
42
TC-TEL
TC-TEL
GX24q-3
GX24q-4
2x42
57
TC-TEL
TC-TEL
GX24q-4
GX24q-5
Circuit diagrams see pages 267 – 270
Power consumption
W
1 x 14.8
2 x 14.8
1 x 18.4
2 x 18.4
1 x 18.0
2 x 18.0
1 x 26.0
1 x 26.0
2 x 26.0
1 x 32.0
1 x 32.0
2 x 32.0
1 x 42.0
1 x 42.0
2 x 42.0
1 x 57.0
(16,1)
132
151,7
167,8
17,9
24
(24)
,6
Ø3
48
(17,9)
36
84
82
INDEPENDENT
TC
Electronic ballast
Type
Ref. No. Voltage AC
50, 60 Hz
V±10 %
ELXd 117.715 188865 220 – 240
ELXd 217.717 188867 220 – 240
ELXd 117.715 188865 220 – 240
ELXd 217.717 188867 220 – 240
ELXd 157.812 188715 220 – 240
ELXd 242.813 188716 220 – 240
ELXd 157.812 188715 220 – 240
ELXd 142.709 188924 220 – 240
ELXd 242.813 188716 220 – 240
ELXd 157.812 188715 220 – 240
ELXd 142.709 188924 220 – 240
ELXd 242.813 188716 220 – 240
ELXd 157.812 188715 220 – 240
ELXd 142.709 188924 220 – 240
ELXd 242.813 188716 220 – 240
ELXd 157.812 188715 220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 60
A1 10 to 50
A1 10 to 60
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
Casing
temperature
tc (°C)
max. 65
max. 70
max. 65
max. 70
max. 75
max. 75
max. 75
max. 65
max. 75
max. 75
max. 65
max. 75
max. 75
max. 65
max. 75
max. 75
System
Casing Output Luminous
factor
W
%
K2
18.0 103.8
K3
33.8
98.5
K2
22.0 105.3
K3
40.7 102.5
K3.1
20.0 100.0
K3.1
38.0 100.0
K3.1
29.0 100.0
K2
27.5 106.8
K3.1
56.0 100.0
K3.1
36.0 100.0
K2
34.8 106.3
K3.1
69.0 100.0
K3.1
47.0 100.0
K2
45.0 103.8
K3.1
90.0 100.0
K3.1
61.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Attachable cord grip
for casing K3.1
Weight: 100 g, unit: 20 pcs.
Ref. No.: 188747
35,7
Complete implementation of the DALI-standard:
addressable, memory store for scenes and groups,
revertive information communication, physical and
RND-selection, standardized lamp characteristic
Low-power design ensures very low standby
power consumption
Electronic Ballasts for TC and T Lamps
ELXs – Warm Start
for T5 and
T8 Lamps
Casing: K20 and K21
Type
Base
W
4
T5
G5
6
T5
G5
8
T5
G5
13
T5
G5
14
T5
G5
T8
G13
15
T8
G13
16
T8
G13
18
T8
G13
21
T5
G5
24
T5
G5
18
18
K21
21
4,4
80
75
141,7
146,7
T
B U I LT- I N
Lamp
Output
K20
41
Electronic built-in ballasts
Casing: heat-resistant polyamide
Power factor: approx. 0.6
(depending on the lamp output)
DC voltage operation: 198–264 V
Push-in terminals with push-button: 0.5–1.5 mm2
RFI-suppressed
For luminaires of protection class I and II
Degree of protection: IP20
Fixing slots for screws M4
For lighting systems with
high switching frequency (> 5/day)
EOL shut down approved
acc. to EN 61347 Test 2
Power consumption
W
1 x 4.6
1 x 4.6
1 x 6.0
1 x 6.0
1 x 7.1
1 x 7.1
1 x 12.0
1 x 12.0
1 x 14.1
1 x 14.1
1 x 13.5
1 x 13.5
1 x 14.1
1 x 14.1
1 x 12.0
1 x 12.0
1 x 15.9
1 x 15.9
1 x 19.1
1 x 19.1
1 x 20.1
1 x 20.1
Circuit diagrams see pages 267 – 270
Electronic ballast
Type
Ref. No.
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
ELXs
188661
188662
188661
188662
188661
188662
188661
188662
188663
188664
188665
188666
188665
188666
188661
188662
188665
188666
188663
188664
188665
188666
116.900
116.903
116.900
116.903
116.900
116.903
116.900
116.903
121.901
121.904
124.902
124.905
124.902
124.905
116.900
116.903
124.902
124.905
121.901
121.904
124.902
124.905
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A3 –15 to 55
A3 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
A2 –15 to 55
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 80
max. 80
max. 85
max. 85
max. 85
max. 85
max. 75
max. 75
max. 85
max. 85
max. 80
max. 80
max. 85
max. 85
System
Casing Output
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
K20
K21
W
5.9
5.9
7.5
7.5
8.6
8.6
13.1
13.1
16.3
16.3
16.2
16.2
17.6
17.6
13.4
13.4
18.5
18.5
21.8
21.8
21.5
21.5
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
133
ELXc – Warm Start for T5 and T8 Lamps
Electronic built-in ballasts
Casing: heat-resistant polycarbonate (K9, K10)
or metal (M8, M9, M10/M11, M22)
Power factor: ³ 0.95
RFI-suppressed
For luminaires of protection class I (metal casing)
For luminaires of protection class I and II
(plastic casing)
Degree of protection: IP20
For lighting systems with
high switching frequency (> 5/day)
T
B U I LT- I N
K9
28,5
new>>
4,2
30,4
359
4,2
350
28,5
K10
40
4,2
4,2
425
5,5
134
Electronic Ballasts for TC and T Lamps
415
ELXc – Warm Start for T5 and T8 Lamps
new>>
B U I LT- I N
T
M8
28
4,25
Ø4
,25
217
4,25
,25
40,6
230
Ø4
220
28,5
M9
4,2
30,4
359
4,2
350
21
4,2
4,2
M10/M11
350/412
30
4,2
4,2
359/425
350/412
M22
5
350
30
Ø4
,2
4,2
8
4
21
Ø4
,2
350
360
Electronic Ballasts for TC and T Lamps
135
new>>
ELXc – Warm start for T8 lamps – Casing: K9, M8 and M9
DC voltage
for operation: 176–264 V
for ignition: 198–264 V
(ELXc 270.206: DC voltage cannot
be reduced to 176 V)
Lamp
Output
Type
Base
W
18
2x18
3x18
4x18
36
2x36
3x36
58
2x58
70
2x70
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
3 x 16.0
4 x 16.0
1 x 32.0
2 x 32.0
3 x 32.0
1 x 50.0
2 x 50.0
1 x 60.0
2 x 60.0
Push-in terminals: 0.5–1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
EOL shut down
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
Circuit diagrams see pages 267 – 270
B U I LT- I N
136.200
236.202
418.204
418.204
136.200
236.202
336.214
158.201
258.203
170.205
270.206
188314
188316
188744
188744
188314
188316
188595
188315
188317
188319
188320
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 55
–20 to 55
–15 to 55
–15 to 55
–20 to 55
–20 to 55
–15 to 50
–20 to 55
–20 to 50
–20 to 55
–20 to 50
T
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 65
max. 70
max. 75
max. 70
max. 65
System
Casing Output Luminous
factor
W
%
K9
19.5 106.0
K9
38.0 104.3
M8
56.0 100.8
M8
71.5
98.9
K9
34.5
96.5
K9
72.0
98.3
M8
105.0
99.4
K9
55.0 100.9
K9
107.0 101.0
M9
67.8 104.3
M9
131.0 104.3
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXc EffectLine – Warm start for T8 lamps – Casing: M8
Push-in terminals: 0.5–1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
EOL shut down
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
18
2x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
Circuit diagrams see pages 267 – 270
136.207
236.208
136.207
236.208
158.209
258.210
188708
188709
188708
188709
188710
188711
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 55
–20 to 50
–20 to 55
–20 to 50
–20 to 50
–20 to 50
Casing
temperature
tc (°C)
max. 60
max. 60
max. 60
max. 60
max. 60
max. 65
System
Casing Output Luminous
factor
W
%
M8
18.4 105.0
M8
35.2 106.0
M8
35.4
97.0
M8
69.7
98.0
M8
52.6 106.0
M8
109.9 105.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXc EffectLine – Warm start for T8 lamps – Casing: M8
Push-in terminals with push-button: 0.5–1.5 mm²
EOL shut down
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
18
2x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
Circuit diagrams see pages 267 – 270
136
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
136.207
236.208
136.207
236.208
158.209
258.210
188704
188705
188704
188705
188706
188707
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 55
–20 to 50
–20 to 55
–20 to 50
–20 to 50
–20 to 50
Casing
temperature
tc (°C)
max. 60
max. 60
max. 60
max. 60
max. 60
max. 65
System
Casing Output Luminous
factor
W
%
M8
18.4 105.0
M8
35.2 106.0
M8
35.4
97.0
M8
69.7
98.0
M8
52.6 106.0
M8
109.9 105.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
ELXc EffectLine II – Warm start for T8 lamps – Casing: M8
B U I LT- I N
Push-in terminals with push-button: 0.5–1.5 mm²
EOL 2 shut down
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
18
2x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
T
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
Circuit diagrams see pages 267 – 270
136.216
136.217
136.216
236.217
158.218
258.219
new>>
188912
188913
188912
188913
188914
188915
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 55
–20 to 60
–20 to 55
–20 to 60
–20 to 60
–20 to 50
Casing
temperature
tc (°C)
max. 65
max. 60
max. 65
max. 70
max. 65
max. 70
System
Casing Output Luminous
factor
W
%
M8
19.8 105.7
M8
38.0 101.6
M8
34.4
97.5
M8
71.9 110.6
M8
56.0 100.8
M8
110.0 101.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXc EffectLine II – Warm start for T8 lamps – Casing: M8
Push-in terminals: 0.5 –1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
EOL 2 shut down
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
18
2x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
Circuit diagrams see pages 267 – 270
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
136.216
236.217
136.216
236.217
158.218
258.219
188868
188869
188868
188869
188870
188871
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 55
–20 to 60
–20 to 55
–20 to 60
–20 to 60
–20 to 55
Casing
temperature
tc (°C)
max. 65
max. 70
max. 65
max. 70
max. 65
max. 70
System
Casing Output Luminous
factor
W
%
M8
19.8 105.7
M8
38.0 101.6
M8
34.4
97.5
M8
71.9 110.6
M8
56.0 100.8
M8
110.0 101.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
137
ELXc – Warm start for T5 lamps – Casing: M8, M10/M11 and K10
DC voltage
for operation: 176–264 V
for ignition: 198–264 V
(ELXc 135.856, 235.857, 149.858,
154.864, 424.379, 180.866, 280.538:
DC voltage cannot be reduced to 176 V)
Push-in terminals: 0.5–1 mm²
(ELXc 424.379: 0.5–1.5 mm²)
Lamp
Output
Type
Base
W
14
2x14
3x14
4x14
21
2x21
24
2x24
3x24
4x24
28
2x28
35
2x35
39
2x39
49
2x49
54
2x54
80
2x80
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
Power consumption
W
1 x 14.0
2 x 14.0
3 x 14.0
4 x 14.0
1 x 21.0
2 x 21.0
1 x 22.5
2 x 22.5
3 x 21.5
4 x 21.5
1 x 28.0
2 x 28.0
1 x 35.0
2 x 35.0
1 x 38.0
2 x 38.0
1 x 49.0
2 x 49.0
1 x 54.0
2 x 54.0
1 x 80.0
2 x 80.0
Circuit diagrams see pages 267 – 270
138
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
EOL shut down approved
acc. to EN 61347 Test 2
T
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
135.856
235.857
414.868
414.868
135.856
235.857
140.862
240.863
424.379
424.379
135.856
235.857
135.856
235.857
140.862
240.863
149.858
249.859
154.864
254.865
180.866
280.538
B U I LT- I N
188093
188094
188438
188438
188093
188094
188140
188616
188116
188116
188093
188094
188093
188094
188140
188616
188095
188617
188142
188618
188144
188619
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 50
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 55
–15 to 50
–15 to 55
–15 to 50
–15 to 55
–15 to 50
Casing
temperature
tc (°C)
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 75
max. 85
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
max. 70
System
Casing Output Luminous
factor
W
%
17.0 110.7
M10
M10
33.4 107.0
49.0 105.4
M8
M8
64.0 102.3
M10
24.0 107.4
M10
50.2 110.6
M10
27.0 114.0
M10
51.0 107.4
K10
76.0
98.2
K10
96.5
98.4
M10
32.0 104.9
M10
60.6 106.2
M10
39.5 102.7
M10
74.5 102.5
M10
43.0 107.0
M10
82.0
97.9
M10
54.0 102.5
M10
113.0 106.6
M10
59.0 101.1
M10
119.0
93.4
M10
87.0
97.6
M11
175.0
97.2
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
ELXc – Warm start for T5 lamps – Casing: M22/M24
DC voltage
for operation: 176–276 V
for ignition: 198– 264 V
Push-in terminals: 0.5–1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
14
2x14
21
2x21
24
2x24
28
2x28
35
T5
T5
T5
T5
T5
T5
T5
T5
T5
G5
G5
G5
G5
G5
G5
G5
G5
G5
2x35
T5
G5
39
2x39
49
T5
T5
T5
G5
G5
G5
2x49
T5
G5
54
2x54
80
2x80
T5
T5
T5
T5
G5
G5
G5
G5
Power consumption
W
1 x 14.0
2 x 14.0
1 x 21.0
2 x 20.5
1 x 23.0
2 x 23.0
1 x 28.0
2 x 28.0
1 x 35.0
1 x 35.0
2 x 35.0
2 x 35.0
1 x 38.0
2 x 38.0
1 x 49.0
1 x 49.0
2 x 49.0
2 x 49.0
1 x 54.0
2 x 54.0
1 x 80.0
2 x 80.0
Circuit diagrams see pages 267 – 270
new>>
EOL shut down approved
acc. to EN 61347 Test 2
Automatic lamp detection (T5 HO/HE)
Optimum pre-heating of the filament ensures
lamps can be ignited within 1 second.
Electronic ballast
Type
Ref. No.
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
ELXc
139.632
239.635
139.632
239.635
139.632
239.635
149.633
249.636
149.633
180.634
249.636
280.637
139.632
239.635
149.633
180.634
249.636
280.637
149.633
249.636
180.634
280.637
188945
188948
188945
188948
188945
188948
188946
188949
188946
188947
188949
188950
188945
188948
188946
188947
188949
188950
188946
188949
188947
188950
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
B U I LT- I N
T
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
System
Casing Output Luminous
factor
W
%
M22
16.0 100.0
M22
31.0 100.0
M22
24.0 100.0
M22
45.0 100.0
M22
26.0 100.0
M22
50.0 100.0
M22
32.0 100.0
M22
61.0 100.0
M22
38.0 100.0
M22
38.0 100.0
M22
76.0 100.0
M24
75.0 100.0
M22
41.0 100.0
M22
81.0 100.0
M22
53.0 100.0
M22
53.0 100.0
M22
105.0 100.0
M24
104.0 100.0
M22
58.0 100.0
M22
115.0 100.0
M22
85.0 100.0
M24
165.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
139
ELXd – Dimmable for T5 and T8 Lamps
28,5
M9
350
4,2
4,2
30,4
359
349,5
1
M23
(3,75)
4,1
21
4,
1
4,75
Ø
360
Ø4
40
4,1
Electronic built-in ballasts
Casing: metal
Power factor: ³ 0.95 at 100 % operation
DC voltage
for operation: 154–276 V
for ignition: 198–264 V
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
RFI-suppressed
For luminaires of protection class I
Degree of protection: IP20
For lighting systems with
high switching frequency (> 5/day)
Suitable for use in luminaires for emergency
lighting systems acc. to VDE 0108
,1
5
(5)
350
M22/M24
5
1–10 V
350/415
30
Ø4
,2
4,2
8
4
21
Ø4
,2
B U I LT- I N
140
T
Electronic Ballasts for TC and T Lamps
350/415
360/423
ELXd – Dimmable 1–10 V for T8 lamps – Casing: M9 and M23
Dimming range:
approx. 1–100 % of lamp power
Control voltage: DC 1–10 V acc. to EN 60929
with earth leakage current 0.6 mA
(protected if connected to mains voltage)
new>>
new>>
new>>
new>>
new>>
new>>
new>>
new>>
Lamp
Output
Type
Base
W
18
2x18
3x18
4x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
3 x 16.0
4 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
Circuit diagrams see pages 267 – 270
118.718
218.719
318.622
418.625
136.720
236.721
158.722
258.723
new>>
For use with open- or closed-loop
control units
Push-in terminals: 0.5–1 mm²
EOL 2 shut down
188873
188874
188596
188599
188875
188876
188877
188878
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 50
A1 –20 to 50
A1 –20 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
1–10 V
B U I LT- I N
T
Casing
temperature
tc (°C)
max. 70
max. 70
max. 75
max. 75
max. 70
max. 70
max. 70
max. 75
System
Casing Output Luminous
factor
W
%
M9
21.0 100.0
M9
41.5 100.0
M23
53.6 100.0
M23
69.3 100.0
M9
37.3 100.0
M9
72.0 100.0
M9
55.0 100.0
M9
109.0 100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
ELXd – Dimmable 1–10 V for T5 lamps – Casing: M22/M24 and M23
Dimming range:
approx. 1–100 % of lamp power
Control voltage: DC 1–10 V acc. to
EN 60929 with earth leakage current 0.6 mA
(protected if connected to mains voltage)
Lamp
Output
Type
Base
W
14
2x14
3x14
4x14
21
2x21
24
2x24
3x24
4x24
28
2x28
35
2x35
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
Power consumption
W
1 x 14.0
2 x 14.0
3 x 14.0
4 x 14.0
1 x 21.0
2 x 21.0
1 x 23.0
2 x 23.0
3 x 23.0
4 x 23.0
1 x 28.0
2 x 28.0
1 x 35.0
2 x 35.0
39
2x39
49
2x49
T5
T5
T5
T5
G5
G5
G5
G5
1
2
1
2
x
x
x
x
38.0
38.0
49.0
49.0
54
2x54
80
2x80
T5
T5
T5
T5
G5
G5
G5
G5
1
2
1
2
x
x
x
x
54.0
54.0
80.0
80.0
Circuit diagrams see pages 267 – 270
For use with open- or closed-loop control units
Push-in terminals: 0.5–1 mm2
EOL shut down approved
acc. to EN 61347 Test 2
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
124.607
224.608
324.623
424.624
139.609
239.610
124.607
224.608
324.623
424.624
154.611
254.612
180.613
249.614
280.630
139.609
239.610
180.613
249.614
280.630
154.611
254.612
180.613
280.630
188336
188337
188597
188598
188338
188339
188336
188337
188597
188598
188340
188341
188342
188343
188604
188338
188339
188342
188343
188604
188340
188341
188342
188604
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
System
Casing Output
M22
M24
M23
M23
M22
M24
M22
M24
M23
M23
M22
M24
M22
M24
M24
M22
M24
M22
M24
M24
M22
M24
M22
M24
W
16.0
31.0
45.3
60.4
23.0
45.0
26.0
50.0
73.4
97.6
31.0
61.0
38.0
75.0
75.0
42.0
82.0
54.0
104.0
104.0
59.0
115.0
88.0
165.0
Luminous
factor
%
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
141
ELXd – Dimmable with push key or DALI for T8 lamps – Casing: M22/M24 and M23
Dimming range:
approx. 1–100 % of lamp power
PUSH: dimmable with usual push key
DALI: poles are not polarity sensitive
(protected if connected to mains voltage)
for use with DALI compatible control units
Push-in terminals: 0.5–1 mm2
EOL 2 shut down
Stand-by power consumption: £ 0.2 W
Complete implementation of the DALI-standard:
addressable, memory store for scenes and groups,
revertive information communication, physical and
RND-selection, standardized lamp characteristic
Low-power design ensures very low standby
power consumption
B U I LT- I N
T
Lamp
Output
Type
Base
W
18
2x18
3x18
4x18
36
2x36
58
2x58
T8
T8
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 16.0
2 x 16.0
1 x 16.0
2 x 16.0
1 x 32.0
2 x 32.0
1 x 50.0
2 x 50.0
Circuit diagrams see pages 267 – 270
142
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
118.615
218.616
318.627
418.629
136.617
236.618
158.619
258.620
188344
188345
188601
188603
188346
188347
188348
188349
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
A1 –20 to 50
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
Casing
System
Output
M22
M24
M23
M23
M22
M24
M22
M24
W
19.0
37.0
53.6
69.3
36.0
69.0
56.0
108.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
Luminous
factor
%
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
ELXd – Dimmable with push key or DALI for T5 lamps – Casing: M22/M24 and M23
Dimming range:
approx. 1–100 % of lamp power
PUSH: dimmable with usual push key
DALI: poles are not polarity sensitive
(protected if connected to mains voltage)
for use with DALI compatible control units
Push-in terminals: 0.5–1 mm2
EOL shut down approved
acc. to EN 61347 Test 2
Stand-by power consumption: £ 0.2 W
Lamp
Output
Type
Base
W
14
2x14
3x14
4x14
21
2x21
24
2x24
3x24
4x24
28
2x28
35
2x35
39
2x39
49
2x49
54
2x54
80
2x80
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
T5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
G5
Power consumption
W
1 x 14.0
2 x 14.0
3 x 14.0
4 x 14.0
1 x 21.0
2 x 21.0
1 x 23.0
2 x 23.0
3 x 23.0
4 x 23.0
1 x 28.0
2 x 28.0
1 x 35.0
2 x 35.0
1 x 38.0
2 x 38.0
1 x 49.0
2 x 49.0
1 x 54.0
2 x 54.0
1 x 80.0
2 x 80.0
Circuit diagrams see pages 267 – 270
Complete implementation of the DALI-standard:
addressable, memory store for scenes and groups,
revertive information communication, physical and
RND-selection, standardized lamp characteristic
Low-power design ensures very low standby
power consumption
B U I LT- I N
T
Electronic ballast
Type
Ref. No.
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
ELXd
124.600
224.601
324.626
424.628
139.602
239.621
124.600
224.601
324.626
424.628
154.603
254.604
180.605
249.606
139.602
239.621
180.605
249.606
154.603
254.604
180.605
280.631
188329
188330
188600
188602
188331
188350
188329
188330
188600
188602
188332
188333
188334
188335
188331
188350
188334
188335
188332
188333
188334
188605
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE* Ambient
temperature
ta (°C)
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
A1 10 to 50
Casing
temperature
tc (°C)
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
max. 75
Casing
System
Output
M22
M24
M23
M23
M22
M24
M22
M24
M23
M23
M22
M24
M22
M24
M22
M24
M22
M24
M22
M24
M22
M24
W
16.0
31.0
45.3
60.4
23.0
45.0
26.0
50.0
73.4
97.6
31.0
61.0
38.0
75.0
42.0
82.0
54.0
104.0
59.0
115.0
88.0
165.0
Luminous
factor
%
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
143
ELXe – Instant Start for T8 Lamps
K9
28,5
Electronic built-in ballasts
Casing: heat-resistant polycarbonate (K9)
or metal (M8)
Power factor: 0.98
DC voltage operation: 198–264 V
Push-in terminals: 0.5–1 mm²
For the automatic luminaire wiring:
IDC terminals for leads H05V-U 0.5
RFI-suppressed
For luminaires of protection class I and II
Degree of protection: IP20
For lighting systems with
low switching frequency (< 5/day)
4,2
30,4
359
4,2
350
M8
Ø4
28
4,25
,25
217
4,25
,25
40,6
230
Ø4
T
B U I LT- I N
220
Lamp
Output
Type
Base
W
15
2x15
18
2x18
4x18
30
2x30
36
2x36
38
2x38
58
2x58
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
T8
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
G13
Power consumption
W
1 x 13.0
2 x 13.0
1 x 16.0
2 x 16.0
4 x 16.0
1 x 30.0
2 x 30.0
1 x 32.0
2 x 32.0
1 x 34.0
2 x 34.0
1 x 52.0
2 x 52.0
Circuit diagrams see pages 267 – 270
144
Electronic ballast
Type
Ref. No.
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
ELXe
218.526
218.526
218.526
218.526
418.215
238.527
238.527
238.527
238.527
238.527
238.527
258.222
258.222
188136
188136
188136
188136
188660
188137
188137
188137
188137
188137
188137
188130
188130
Voltage AC
50, 60 Hz
V±10 %
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
220 – 240
EE*
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Ambient
temperature
ta (°C)
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–10 to 55
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
–20 to 50
Casing
temperature
tc (°C)
max. 60
max. 60
max. 60
max. 60
max. 65
max. 60
max. 60
max. 60
max. 60
max. 60
max. 60
max. 60
max. 60
System
Casing Output
K9
K9
K9
K9
M8
K9
K9
K9
K9
K9
K9
K9
K9
W
14.5
29.0
18.0
34.0
68.0
31.0
62.0
35.0
68.5
35.0
70.0
54.0
108.0
* Energy efficiency: Step 2: EEI= A3, minimum EU energy efficiency requirements as of 2012 |
Step 3: A2, minimum EU energy efficiency requirements as of 2017
Electronic Ballasts for TC and T Lamps
Luminous
factor
%
100.0
100.0
100.0
100.0
98.2
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
Accessories for Dimmable Electronic Built-in Ballasts
1 2 3 4
80
67
Fuse
Max.
Ø 50
Ø 50
32
7
12 9
12
M10 x 0,75
Ø 38
Ø4
83
46
13
28
33,5
83
13
Lamp
4,5
42
14
25
58,5
14
25
58
Multi sensor
Dimensions: 58.5x 70.5x 42 mm
With the sensor the lighting can be kept
on a pre-defined level
With integrated motion detector
max. 50 EBs per multi sensor
Weight: 125 g, unit: 25 pcs.
Ref. No.: 172777
80
70,5
Light sensor
Constant light control with clamp
fastening for fluorescent lamps T8 (T26)
and compact fluorescent lamps
Dimensions: 33.5x 40x 96 mm
With connection lead: 2x 0.24 mm2
Length: 800 mm
max. 50 EBs per light sensor
Weight: 55 g, unit: 60 pcs.
Ref. No.: 172776
67
32
Manual controller
Dimmer for EB with low-voltage interface 1–10 V
Dimensions: 67x 67x 51 mm
Push-button change-over switch with stud 4 mm
for installation in flushtype boxes with Ø 55 mm
max. 50 EBs per dimmer
Weight: 60/30 g, unit: 25 pcs.
Without cover plate
Ref. No.: 172778
Cover plate with rotary knob
Dimensions: 80x 80x 9 mm
Ref. No.: 172775 white
1
33
8
8
17–32
Ø 26 mm
21–36
Ø 16 mm
Electronic Ballasts for TC and T Lamps
145