By Jacob Ritz
Kelly Clark
Zach Beckman
MUON DEFLECTION
Setup
Box of
magnets
Magnetic field
~0.42 mT
Detector B
Detector D
Detector A
Muon
A Graphs
A calibration with B constant
16
C
O
U
N
T
S
P
E
R
S
E
C
14
12.9
12
11.2
10.87 11.07
10.17
10
8
6
4.5
4
2
0.47
0
0
0.1
0.2
0.3
0.4
0.5
Voltage
0.6
0.7
0.8
0.9
A Singles Rate
350
306.77
300
250
200
Series1
150
100
100.2
50
17.1
0.57
0
0
0.1
0.2
0.3
0.4
0.5
Voltage
0.6
0.7
0.8
0.9
B Graphs
14
C
O
U
N
T
S
P
E
R
B Coincidence rate wit A constant
12
11.83
11.27
11.05
10.5
10
8
7.95
6
B single rate
4
S
E
C
2
0.77
0
0
0
0.1
0.2
0.3
0.4
0.5
-2
Voltage
0.6
0.7
0.8
B singles rate
C
O
U
N
T
500
467.67
450
400
350
P
E
R
S
E
C
300
250
200
150
140.13
100
50
28.98
0
2.05
0.05
0
0.1
0.2
0.3
0.4
Voltage
0.5
0.6
0.7
0.8
0.9
D Graphs
14
C
O
U
N
T
S
P
E
R
D Coincidence A constant
12.833
12
11.1711.33
10
8.5
8.417
7.917
7.42
8
6
4
S
E
C
3.33
2
1.08
0
0
0.1
0.2
0.3
0.4
0.5
Voltage
0.6
0.7
0.8
0.9
D singles
300
C
O
U
N
T
S
P
E
R
S
E
C
D singles
250
237.633
200
150
100
50
32.57
0
0.1
0.2
0.3
0.4
Voltage
-50
0.6
0
0
0.5
0.6
0.7
0.8
0.9
C graphs
 Our C detector at the time was not
functioning properly (small light leak) so we
decided to take it out of our magnet trials to
simplify it. We later fixed the detector and
recalibrated it, and it is now functioning fine.
Hypothesis
 We thought that if we put up a magnetic field
above the detector then the field could curve
muons and other particles off the path of
hitting all 3 detectors.
Magnet Data
T
R
I
A
L
S
(top without magnets bottom with magnets) (error was 50 counts in 30 min)
2064
3
2199
2
2045
1
0
500
1000
1500
2000
Counts in 30 minute trial
241
3
2
2337
1
2327
0
500
1000
1500
2000
2500
Total Counts In 90 Minutes
7400
7200
7000
6800
6600
6400
7078
6200
6000
6308
5800
5600
No Magnets
With Magnets
Results
 Our magnet array did not deflect many
muons, but it increased our count rate. We
are thinking about why this would happen
but still have not found an answer
Next Step
 If we were to continue out experiment to find
out why we got more counts we would…
 Change the orientation of the magnet box.
 Change the magnetic field
 And make a better structure to angle our
detectors
Directional experiment
 We put 2 detectors on a box 1 foot apart and
then tilted it to find out where a majority of
muons were coming from in orders to see if
we were curving muons into out detectors
with our magnets
 We found that many more muons were
coming from above us rather than from an
angle
Data
Electron theory
 We thought that it was possible that we were
curving particles with less momentum int out
detectors